Rationale for White Oil
Pipeline
Key Project Information
Salient Features
Milestones
White Oil Pipeline Stations
Environment Friendliness
HOME > WHITE OIL PIPELINE SYSTEM > WOP STATIONS
 
WOP Pipeline System consists of the following stations and terminals.
1. Port Qasim Receives Imported Product and provides storage and pumping facility.
2. Bubak Future Station
3. Shikarpur Pumping Station as well as terminal
4. Fazilpur Future Station
5. Mahmood Kot Receives product sent from Port Qasim, stores it and transfers it to OMC’s and PARCO System
 
STORAGE CAPACITY OF THE SYSTEM:
TOTAL TANK STORAGE (WOP SYSTEM) 221800 TONS
LINE FILL (WOP) 216000 TONS
OVERALL STORAGE OF WOP SYSTEM 437800 TONS
 
IMPORTANT DATA OF THE STATIONS
Port Qasim
TOTAL STORAGE CAPACITY 108000 Tons
NO OF TANKS 04 Nos. tanks, each of 27000 Tons
FUTURE TANK 02 Nos. tanks as per future requirement
BOOSTER PUMPS 03 Nos. each of 415 HP, 1180 M³/H
STRAINERS 02 Nos. (Prior pumping)
MAIN LINE PUMPS 04 Nos. each of 2345 HP, 1180 M³/H
METERING STATION 02 Nos.
PIG LAUNCHER 01 No
 
Shikarpur
TOTAL STORAGE CAPACITY 5800 TONS
NO OF TANKS 02 Nos. each of 2900 TONS
FUTURE TANKS NIL
STRAINERS 02 Nos
BOOSTING PUMPS NIL
MAINLINE PUMPS 04 Nos. each of 2345 HP, 1180 M³/H
TRANSFER PUMPS 02 Nos. each of 335 HP, 250 M³/H
METERING STATIONS 02 Nos.
PIG RECEIVER 01 NO
PIG LAUNCHER 01 NO
 
Mahmood Kot
TOTAL STORAGE CAPACITY 108000 Tons
NO OF TANKS 04 Nos. tanks, each of 27000 Tons
FUTURE TANK 02 Nos. tanks as per future requirement
BOOSTER PUMPS NIL
STRAINERS 02 Nos. (Prior pumping)
MAIN LINE PUMPS NIL
TRANSFER PUMPS 03 Nos. each of 422 HP, 500 M³/H
METERING STATION NIL
PIG RECEIVER 01 NO
HEADERS CONNECTED 03 Nos. (New OMCs Header, JIMCO Header & MFM Header)
 
 
Telecom, SCADA, MOVs, NOVs, CP & MICROWAVE STATIONS
For remote operation, monitoring and communication; each section and station has Telecom & SCADA installations and equipments. Both the systems run through microwaves signals for which microwave radios, transmitters, receivers, multiplexers, PABAX, booster towers and other equipments are installed through out the line and on stations as well. At each station, there are MCC (master control centre) or control buildings, from where; the shift staffs remotely controls the whole operation.
 
Key Personnel at the Stations & Terminals
Following are the key personnel based on any Station / Terminal.
  1. Station In-charge
  2. Operations Engineer
  3. Administrative Officer
  4. Safety & Security Officer
Names of Persons in charge of Stations:
Station / Terminal Key Person Designation Contact
      021-5090114-25
Port Qasim S. Younus Ali Station Incharge Ext. 40-2004
Bubak A.D. Ghoto Station Incharge Ext. 72-2004
Shikarpur Sohail Akhtar Station Incharge Ext. 73-2004
Fazilpur Niaz Ahmed Dawach Station Incharge Ext. 74-2004
Mahmood Kot Muhammad Iqbal Station Incharge Ext. 75-2004
 